Siemens RUGGEDCOM WIN5214 Installation Manual page 22

Hide thumbs Also See for RUGGEDCOM WIN5214:
Table of Contents

Advertisement

Chapter 2
Installing the Device
Figure 11: CAT-5e PoE Cable Pin-Out
1. Pin 1
2. Pin 8
7.
Slide the wires into the loading bar and then pull the loading bar down until its face is 16 mm (0.63 in) from
the wire jacket. If necessary, use pliers to hold the wires while pulling the loading bar.
1
Figure 12:
1. Loading Bar
8.
Trim the wires until they are flush with the face of the loading bar.
9.
Insert the wires and loading bar into the plug body. Make sure:
• the cable is pushed to the front of the plug body
• the spine of the strain relief on the plug body covers the drain wire
10. Bend the strain relief until it is flat against the jacket and foil.
11. Crimp the plug and strain relief using a standard crimping tool.
12. Trim away any excess foil or drain wire extruding from the strain relief.
13. Slide the connector components up to the plug body.
14. Insert the modular plug into the plug housing.
16
2
1
2
2. Wires
3. Pin 1
4. Pin 8
Pin
Color
Number
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
2
1
3
RUGGEDCOM WIN5214
Installation Guide
Description
ETH Data
TP0+
ETH Data
TP0-
ETH Data
TP1+
48 V
TP2+
48 V
TP2-
ETH Data
TP1-
RTN (-)
TP3+
RTN (-)
TP3-
1
4
Assembling the PoE Cable

Advertisement

Table of Contents
loading

Table of Contents