Model Number Designation

1.1
MODEL CAT3-(
PULSE INPUT
LINEARIZED PULSE OUTPUT
LINEARIZED ANALOG OUTPUT
POWER SUPPLY
ALARM OUTPUT
ENCLOSURE STYLE
SPECIAL FEATURES
PULSE INPUT
MODEL CAT3-(
( A )
OPTION
(1)
MAG COIL, PULSE, DRY CONTACT
(2)
MC3P
(3)
ISOLATED PULSE, RPM, RPR AND HALL EFFECT COILS
LINEARIZED PULSE OUTPUT
MODEL CAT3-( )-(
( B )
OPTION
(1)
0-5 TTL / CMOS
(2)
OPEN COLLECTOR
(3)
OPEN COLLECTOR WITH PULL UP TO V+
(4)
AC SQUARE WAVE
(5)
0-10V SQUARE WAVE
NOTE:
NOT RECOMMENDED FOR USE AS A FLOW RATE SIGNAL.
MAXIMUM INPUT SENSOR FREQUENCY ALLOWED IS 100HZ.
LINEARIZED ANALOG OUTPUT
MODEL CAT3-(
( C )
OPTION
(1)
4-20 MA
(5)
1-5 VDC
POWER SUPPLY
MODEL CAT3-(
( D )
OPTION
(DC)
13-30 VDC
(AC)
100-240 VAC
NOTE: WHEN (AC) IS SELECTED, THE ALARM OPTION IS NOT AVAILABLE.
USE REMOTE ACC39B POWER SUPPLY IF REQUIRED.
CAT3
A
A
)-( )-(
)-(
)-(
B
)-( )-( )-(
)-(
)-(
C
)-(
)-(
)-(
)-(
D
)-(
B
)-(
C
)-(
D
)-(
)-(
)-(
)
)-(
)-(
)
)-(
)-( )-(
)
)-(
)-(
)-( )
Introduction
E
)-(
F
)-( G)
HP-312
3