■ Setting record
 Record any changes to the settings in the following table.
Function
Setting
number
11
Filter sign
20
Ceiling height
22
Outlet directions
23
Vertical wind direction adjustment range
30
Room temperature control for indoor unit sensor
31
35
Room temperature control for wired remote control-
ler sensor
36
40
Auto restart
42
Room temperature sensor switching
44
Remote controller custom code
46
External input control
48
Room temperature sensor switching (Aux.)
49
Indoor unit fan control for energy saving for cooling
60
Switching function for external outlet terminal
After completing the function setting, be sure to turn off the power and turn it on again.

8. CHECK LIST

Pay special attention to the check items below when installing the indoor unit(s). After
installation is complete, be sure to check the following check items again.
CHECK ITEMS
Has the indoor unit been installed
correctly?
Has there been a check for gas
leaks (refrigerant pipes)?
Has heat insulation work been
completed?
Does water drain easily from the
indoor units?
Are the wires and pipes all con-
nected completely?
Is the connection cable the specifi ed
thickness?
Are the inlets and outlets free of any
obstacles?
After installation is completed, has
the proper operation and handling
been explained to the user?

9. TEST RUN

Check items
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do airfl ow direction louvers operate normally?
(4) Is the drain normal?
(5) Do not have an abnormal noise and vibration during operation?
Do not operate the air conditioner in test run for a long time.
[Operation method]
Depending on your installation, choose from the following:
By the wireless remote controller (with [TEST RUN] button)
• To start test run, press the [START/STOP] button and the [TEST RUN] button on the
remote controller.
• To end test run, press the remote controller [START/STOP] button.
By the indoor unit or IR receiver unit
• To start test run, press the [MANUAL AUTO] button of the unit for more than 10 seconds
(forced cooling).
• To end test run, press the [MANUAL AUTO] button for more than 3 seconds or press
the remote controller [START/STOP] button.
By the wired remote controller
• For the operation method, refer to the installation manual and the operating manual of
the wired remote controller.
The Operation indicator lamp and Timer indicator lamp will simultaneously fl ash during the
test run mode.
Heating test run will begin in a few minutes when HEAT is selected by the remote controller
[reverse cycle model only].
Setting value
Cooling
Heating
Cooling
Heating
If not performed correctly
CHECK BOX
Vibration, noise, indoor unit may
drop
No cooling, No heating
Water leakage
Water leakage
No operation, heat or burn dam-
age
No operation, heat or burn dam-
age
No cooling, No heating

10. FINISHING

• After checking for gas leaks (refer to the Installation Manual of the outdoor unit),
perform this section.
• Install heat insulation around both the large (gas) and small (liquid) pipes. Failure to
do so may cause water leaks.
After checking for gas leaks, insulate by wrapping insulation around the 2 parts (gas and
liquid) of the indoor unit coupling, using the Coupler Heat Insulation.
After installing the Coupler Heat Insulation, wrap both ends with vinyl tape so that there is
no gap.
Coupler heat insulation
Body
Be sure to overlap
the insulation
No gap
Must fi t tightly against body without any gap.

11. CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operating manual:
(1) Starting and stopping method, operation switching, temperature adjustment, timer, air
fl ow switching, and other remote controller unit operations.
(2) Cleaning and maintenance of the product, and other items such as air fi lters and air
louvers if applicable.
(3) Give the operating and installation manuals to the customer.
(4) If the signal code is changed, explain to the customer how it changed (the system
returns to signal code A when the batteries in the remote controller unit are replaced).
*(4) is applicable to using wireless remote controller.

12. ERROR CODES

If you use a wired type remote controller, error codes will appear on the remote controller
display. For more information, refer to the installation manual of the remote controller. If you
use a wireless remote controller, the lamps on the IR receiver unit will output error codes
by way of blinking patterns. See the lamp blinking patterns and error codes in the table
below. An error display is displayed only during operation.
Error display
TIMER
ECONOMY
OPERATION
lamp
lamp
lamp (green)
(orange)
(green)
(1)
(1)
(1)
(2)
(1)
(5)
(1)
(6)
(1)
(8)
(2)
(1)
(2)
(2)
(2)
(3)
(2)
(4)
(2)
(6)
CAUTION
No gap
Coupler heat
insulation
CAUTION
Wired
remote
Description
controller
Error code
Serial communication error
Wired remote controller
communication error
Check run unfi nished
Peripheral unit transmission PCB
connection error
External communication error
Unit number or Refrigerant circuit
address setting error
[Simultaneous Multi]
Indoor unit capacity error
Combination error
• Connection unit number
error (indoor secondary unit)
[Simultaneous Multi]
• Connection unit number error
(indoor unit or branch unit)
[Flexible Multi]
Indoor unit address setting error
En-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents