Liquid Orifice Overview; Enabling The Application - ABB Totalflow uFLO 6213 Application Manual

G3 liquid orifice measurement
Table of Contents

Advertisement

1.0

LIQUID ORIFICE OVERVIEW

The Liquid Orifice measurement application is designed to operate in conjunction with
a flow computer and measure liquid volumes for a given material. This application is
available for both Totalflow XSeries and microFLO devices.
This application is designed to perform calculations based on the standards
determined in the API Manual of Petroleum Measurement Standards, Liquefied
Petroleum Gas Measurement.
2.0

ENABLING THE APPLICATION

The following steps will instruct the user on how to enable the Liquid Orifice
application within PCCU.
1) Start PCCU. Once connected, move into Entry mode.
2) Move to the top of the tree-view, and click on the Station ID caption. This will
3) Click on the Applications tab (see Figure 1).
4) Within the Application tab, the user will instantiate the Liquid Measurement
5) Upon location, click in the Type field. From the drop-down list, select Liquid
6) The user can then look at the tree-view. They will notice a Flow Measurement
2012981-001 rev. AB
A liquid orifice measurement application is not available for
XSeries G4 devices at this time.
It should be noted that the application might already be enabled,
based on the device's setup. If this is the case, skip the following
procedure and move to Application Defaults.
bring up the main station setup tabs.
application. Locate an available slot (measurement applications need to be
turned on within slots 11-18).
Measurement. Once selected, click the Send button.
application has been added.
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents