Troubleshooting

WARNING:
To reduce the risk of fire,
electric shock, or injury,
unplug machine from
outlet before servicing.
Reduced spray or no spray.
Possible Causes
Bladder may be empty
1
SmartMix may be empty
2
The lint screen may be clogged
3
Tank-in-Tank may not be seated properly
4
Pump may have lost prime
5
The Pump Belt may be broken
6
Insert
Screwdriver
Blade Here
DirtLifter PowerBrush does not turn.
Possible Causes
The Brush Belt or Pump Belt
1
may be broken
Remedies
Turn power OFF, refill tank with hot tap water.
1
Refill bottle with formula.
2
Turn power OFF, clean out lint screen,
3
follow step 2 on page 8.
Turn power OFF; remove and reseat tank.
4
Turn power OFF; after 1 minute, turn
5
ON and depress Spray trigger.
Turn power OFF and unplug machine
6
from outlet. To check if a Pump Belt
has broken, you will need a flathead
end into the lower slot of the Belt
Access Door to release the latch.
If necessary, insert the blade end into
the upper slot to release the upper
latch. Examine for belt breakage. You
should be able to see the Pump Belt
looped around the motor shaft. If it is
broken or missing, please refer to the
part numbers and descriptions on
Lift Here
page 19 before calling BISSELL
Consumer Services. Complete
installation instructions will accompany
the replacement belt.
Remedies
Turn power OFF and unplug machine
1
from outlet. To check if a Brush Belt
has broken, you will need a flathead
end into the lower slot of the Belt
Access Door to release the lower latch.
If necessary, insert the blade end into
the upper slot to release the upper
latch. Examine for belt breakage. If
broken, refer to pages 13-16.
screwdriver. Insert the blade
screwdriver. Insert the blade