5.16. Test Mode 25 (Adjust Pen Voltage)

Test Mode 25 Operation
Step
1
Standby.
2
Press "FUNCTION".
3
Press "#", " ", "#", "#".
4
Press "2", "5", and "START/SET".
6
Press ten key. (ex. 60)
"0", "6", "0", "0"
7
Press "START".
8
Press "STOP" to return to standby.
Note:
This Test Mode 25 have to operate when SC PC Board or PENC PC Board has been replaced.
At Above Step 6. you have to program the value which is labeled on the IC1 of PENC PC Board as
describe in below.
Each value requier 2 digits input. Refer to Following table.
Operation or Unit Condition
CNP54
IC1
You have to program this value printed on the label by Test Mode25.
LABEL
12 - JUL 15:00
DEFERRED XMT?
TEST MODE (< >)
PEN VOLTAGE = 5
PEN VOLTAGE = 60
TEST MODE (< >)
12 - JUL 15:00
CNP52
CNJ57
Input No
0
"0", "0"
1
"0", "1"
2
"0", "2"
3
"0", "3"
4
"0", "4"
5
"0", "5"
6
"0", "6"
7
"0", "7"
8
"0", "8"
9
"0", "9"
A
"0", "0"
B
"1", "1"
C
"1", "2"
D
"1", "3"
E
"1", "4"
F
"1", "5"