5.6.
Test Mode 5 (Tonal Signal & Binary Signal Generation)
This test mode is used to check the tonal signal output.
Signals can be output to the line using the following procedure.
Step
1
Standby.
2
Press "FUNCTION".
3
Press "#", " ", "#", "#".
4
Press "5" and "SET".
5
Select required Signal by Dial button.
6
Press "START" to send Signal.
7
Press "STOP" to stop sending.
8
Repeat Step 5 to 7.
9
Press "STOP" to return to testmode standby.
Operation or Unit Condition
Number
1
2
3
4
5
6
7
8
9
0
*
#
# and >
# and 2 times of >
# and 3 times of >
# and 4 times of >
# and 5 times of >
# and 6 times of >
# and 7 times of >
# and 8 times of >
# and 9 times of >
# and 10 times of >
# and 11 times of >
# and 12 times of >
Tonal Signal Table
12-MAY 15:00
DEFERRED XMT?
TEST MODE (< >)
9600bps
TONE=9600bps
TONE=9600bps ON
TONE=9600bps OFF
TEST MODE (< >)
Signals
V29 9600 bps
V29 7200 bps
V27 ter 4800 bps
V27 ter 2400 bps
300 bps
1100 Hz
1300 Hz
1400 Hz
1650 Hz
2100 Hz
1850 Hz
33600 bps
31200 bps
28800 bps
26400 bps
21600 bps
Ans AM
CM
JM
14400 bps
12000 bps
TC 9600 bps
TC 7200 bps
LINE
112
LCD Display