Test Mode 1 (Function Parameter Setting) - Panasonic UF-E1 Service Manual

Hide thumbs Also See for UF-E1:
Table of Contents

Advertisement

5.3.

Test Mode 1 (Function Parameter Setting)

Use the following procedure to change the function parameters.
Step
Operation or Unit Condition
1
Standby.
2
Press "FUNCTION".
3
Press "#", " ", "#", "#".
4
Press "1" and "START".
5
Enter the Function Parameter Number.
Ex: Changing "TX JAM CHECK" -Enter"03".
6
Press "START".
7
Enter the new setting value.
Ex: Enter "V" or "
8
Press "START". The new value will be stored and the next
parameter will be displayed.
9
Press clear and Repeat steps 5 through 8 to change other
Function Parameters or Press "STOP" twice to return to
standby.
Note: The following buttons provide these functions in the test mode:
" START " : The new setting value is stored in the machine.
" V " : Scroll the function parameter number down.
"
" : Scroll the function parameter number up.
^
" for Constant.
^
12-MAY 15:00
DEFERRED XMT?
TEST MODE
TEST MODE (< >)
PARAMETER No.3
TX JAM CHECK : ON
TX JAM CHECK : OFF
HEADER PRINT : IN
12-MAY 15:00
103
LCD Display
UF-E1