Appendix A: Transmitter Behavior - CDI Traxall X200 User Manual

Multifrequency pipeline pig tracking transmitters
Table of Contents

Advertisement

APPENDIX A: TRANSMITTER BEHAVIOR

Frequency & Power
Whether in Constant or Pulse mode, an ac ve transmi er is sending a
signal at a frequency ranging from about 15 to 30 Hz (with 22 Hz being the
tradi onal or "legacy" frequency).
The Power slider control increases transmi er range (at the expense of
ba ery life). Here, we see a transmi er set to run at 50% power. Therefore,
one complete cycle (Hz) consists of equal "posi ve" and "nega ve" duty
cycles. (Assume a constant ba ery voltage regardless of se ngs.)
As the Power slider is moved to the right, transmi er power is
increased. A 90% power se ng would resemble this:
TRAXALL X200 Series Mul frequency Transmi er User Guide
Page 27 of 32
one complete cycle (Hz)
+
+
+
+
one complete cycle (Hz)
+
+
+
+

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents