c. Start SSHTerm, log in as "manager" and select the server from the displayed
menu.
This will display the console, which you can use to enter CLI commands on the
server to complete the following steps. Refer to the Hitachi High-performance
NAS Platform Command Line Reference for more information on the
commands used below.
d. Verify which addresses are currently assigned to each aggregation by entering
the following command:
evsipaddr -l
e. Remove each IP address assigned to aggregations 3 through 6 by entering the
following command:
evsipaddr -e evs_id -r -i ip_address
where evs_id is the aggregation (3, 4, 5, or 6) and ip_address is the IP
address to remove.
f.
Add each IP address you previously removed to aggregation 1 or 2 by entering
the following command:
evsipaddr -e evs_id -a -i ip_address -m ip_mask -p ag_port
where evs_id is the aggregation (1 or 2) and ip_address is the IP address to
add, ip_mask is the IP address mask for the IP address being added, and
ag_port is the aggregation (1 or 2) to which the IP address is to be added.
g. Verify which GE member interfaces belong to which aggregation group by
entering the following command:
agg
h. Remove any GE interfaces numbered between 3 through 6 from aggregations
1 and 2 by entering the following command:
aggedit remove agX geY
where X is the aggregation and Y is the GE interface to remove.
i.
Delete aggregations 3 through 6, if present, by entering the following
command:
agg delete agN
where N is the aggregation to remove (3, 4, 5, or 6).
5. Shut down the server.
6. Replace the NIM 1060 with the NIM 1200.
See
"Replacing a Hitachi High-performance NAS Platform™ Module (Non-
Upgrade)," on page 25
7. Restore the physical network connections.
Once the NIM 1200 is installed, public data network connections from the
NIM 1200 must now be plugged into 10 GbE switch ports, rather than 1 GE
switch ports.
Ensure that the private management network port (10/100 port) is
reconnected. (Note: the NIM 1200 has a single 10/100 port, whereas the
NIM 1060 has four.)
Hardware Reference
for details.
Replacing System Components
29