Replacing A Nim 1060 With A Nim 1200; Prerequisites - Hitachi 2000 Series Hardware Reference Manual

High-performance nas platform
Table of Contents

Advertisement

If the FSA/FSX module does not have a package file pre-loaded, you must
load the package via the SSLoader.
If the FSA/FSX module does have a package file, check the currently
loaded package version against the version recorded in step 3. If the
package already loaded on the FSA/FSX module is older than the version
recorder in step 3, you must load the most current firmware package via
the SSLoader.
If it is necessary to reload software, reload the complete software image file (do
not strip unused files). Refer to the Hitachi High-performance NAS Platform
System Installation Guide for instructions on using SSLoader and loading the
software.
8. Perform steps 7 through 11 of the procedure described in
with a NIM 1200," on page
9. Swap in the FSB and SIM according to the procedure described in
Hitachi High-performance NAS Platform™ Module (Non-Upgrade)," on page
10. Reboot and verify that the hardware database has been updated.
To verify hardware database has been updated, enter the following CLI command:
dblog |grep HWDB
The output of this command should be similar to the following:
HWDB scores: NIM 7, FSM 7, SIM 7
If any module has a score lower then 7, the hardware database is incorrect. In this
situation, contact Hitachi Data Systems Technical Resource Center (TRC) for
assistance.

Replacing a NIM 1060 with a NIM 1200

The NIM module has several variations with different number and types of ports. Aside
from labelling, the only external changes are the number and type of Ethernet port used
to connect to the customer's (public) network and the private management network.
NIM Model
1045
1050 and 1060
1200

Prerequisites

Before attempting to upgrade a server from a NIM 1060 to NIM 1200, ensure the
following:
You have reviewed the procedure below to familiarize yourself with the NIM 1060
and NIM 1200, and module replacement procedures.
Hardware Reference
27.
Table 21: NIM Module Ports
Public (Customer)
Network Ethernet Ports
4 (GE)
6 (GE)
2 (10 GbE)
Replacing System Components
"Replacing a NIM 1060
"Replacing a
Private Management
Network Ethernet Ports
4 (10/100)
4 (10/100)
1 (10/100)
25.
27

Hide quick links: