Panasonic Panafax UF-885 Service Manual page 157

Hide thumbs Also See for Panafax UF-885:
Table of Contents

Advertisement

No.
Parameter (see Note 3)
075
MH/MR/MMR/JBIG
076
Not used
077
RX JAM LENGTH
078
Not used
079
080
DOC TOP FEED
081
DOC END FEED
082
JAM LENGTH
083
Not used
084
LINE AS NO PAPER
085
Not used
086
REDUCTION FINE
087
DARKER LEVEL
088
NORMAL LEVEL
089
LIGHTER LEVEL
090
CONTINUE FROM ADF
(See Note 4)
091
Not used
092
SMOOTHING
093
Not used
~
099
Signal
MCF/PIP
RTP/PIP
RTN/PIN
Note 3:
The default setting of parameters depends on the country's specifications or regulations. Print the Function Parameter List to
confirm the default settings.
Note 4:
This parameter will be available as a running change in the future.
Function Parameter Table
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR (MH or MR or MMR)
4 = JBIG
1 = Off (unlimited)
2 = 2 m
3 = 8 m
-5.0 mm
~
+5.0 mm
-5.0 mm
~
+5.0 mm
1 = 1 m
2 = 2 m
3 = 8 m
4 = Unlimited
1 = Ring (ring)
2 = Busy (keep line busy)
1 = Off
2 = On
0 = Lightest Contrast
~
15 = Darkest Contrast
1 = Off
2 = On (Default)
1 = Off
2 = On
Note 1: No. 070 LINE ERROR-Transmit condition of RTP/PIP or RTN/PIN
1:128
2:256
0-31
0-63
32-63
64-127
64-127
128-255
Note 2: No. 071 TOTAL ERROR-Transmit condition of RTP/PIP or RTN/PIN
Signal
1:5%
MCF/PIP
0-2
RTP/PIP
3-4
RTN/PIN
5-
Selections
Selects the coding scheme.
Selects the maximum length of a received
document that can be printed.
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
Selects the maximum length of the document that
can be scanned.
Selects whether to ring or send a busy tone to the
remote station when the recording paper runs out
or the unit cannot receive because of any trouble.
Selects whether the resolution is preset to Fine,
when sending with reduction B4→A4.
Selects the contrast level.
0←
Lightest← →Darkest
Selects whether the machine will continue the
transmission and send the remaining document(s)
from the ADF when the memory reaches 100%
(Memory Overflow) while storing the documents.
Selects whether the smoothing function is
available.
Setting
3:512
4:1024
0-127
0-255
128-255
256-511
256-511
512-1023
Setting
2:10%
3:15%
0-4
0-7
5-9
8-14
10-
15-
Service Modes
Function
→15
5:2048
6:Off
0-511
Always
512-1023
-
1024-2047
-
4:20%
0-9
10-19
20-
157

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Panafax uf-895

Table of Contents