Panasonic Panafax UF-885 Service Manual page 126

Hide thumbs Also See for Panafax UF-885:
Table of Contents

Advertisement

Panasonic UF-885 / 895
4.4.10 Improper Fusing (Printed image does not bond to the paper)
P
START
Yes
Is the recording paper damp?
No
Replace the paper.
No
Is the Fuser Unit normal?
Yes
Replace the Fuser Unit. (See Note)
END
Note:
Replace the entire Fuser Unit when the Thermostat and / or the Thermistor becomes open-circuit.