NOTE: Before starting the machine, make sure the machine is level within 1/8 inch in all directions, the bin or
dispenser leg height can be adjusted by rotating the leg foot.
After verifying proper voltage, water
supply, drains and breathable air space
around the unit, press and quickly release
the ON/OFF button behind the unit front
panel. The indicator light will change from
a solid red to solid blue in color.
Follow the sequence of operation
described under "Operation of CNM
Series Cuber" in this manual. Check
operation of each component through the
cycle as explained in this section.
Bridge Thickness Adjustment
Once the unit has gone through a harvest
cycle, verify the bridge thickness (3/16"
thick for units less than 400 lbs. and 1/8"
for 400 lbs. and above) across the middle
of the ice slab on the second batch
produced. The ice thickness can be
changed on the Float Housing by turning
the adjustment clockwise to decrease the
bridge thickness and counter-clockwise
to increase the bridge thickness. You will
hear a "click" with each adjustment. It is
recommended adjustments be made one
or two "clicks" at a time.
© 2018, Cornelius Inc.

START-UP PROCEDURE

- 13 -
Installation Guide and Owner's Manual
Access to Water Level Adjustment
Figure 10.
Figure 11.
Publication Number: 548000033
Lowers Float;
increases bridge
thickness.
Raises Float;
decreases bridge
thickness.