Huawei OceanStor V3 Series Features Manual page 78

Block
Hide thumbs Also See for OceanStor V3 Series:
Table of Contents

Advertisement

OceanStor V3 Series
Remote Replication Feature Guide for Block
Step 1 Map all the primary and secondary LUNs in the consistency group to the host.
1.
2.
To check on a standby server whether data replication succeeds, you need to mount the secondary LUN to the
standby server. Before mounting the secondary LUN, split the LUN and set Status of Secondary Resource
Protection to Read/Write.
Step 2 Check whether data replication succeeded.
1.
2.
3.
Step 3 Check whether a primary/secondary switchover can be performed on the secondary site.
1.
2.
Issue 06 (2018-01-30)
Log in to DeviceManager. Choose
Create to create LUN groups and add the primary and secondary LUNs of the remote
replication task to corresponding LUN groups.
Choose
Provisioning > Mapping View. Choose the mapping view that the host
group which holds the application servers belongs to. Then add the newly created LUN
group to this mapping view.
NOTE
Log in to the application server at the primary site and write file X1.txt to all primary
LUNs of the consistency group. When Running Status of the consistency group is
Normal, go to the next step.
Log in to DeviceManager at the primary site. Choose Data Protection > Remote
Replication > Remote Replication Consistency Group. Click the remote replication to
be synchronized. Choose More > Synchronize to perform the synchronization manually.
Log in to the standby server at the secondary site to check whether data file X1.txt exists
on the secondary LUNs of the consistency group.
– If yes, data replication succeeded.
– If no, log in to DeviceManager at the primary site. Choose Data Protection >
Remote Replication > Remote Replication Consistency Group. Click the
consistency group to be synchronized. Choose More > Synchronize to perform the
synchronization manually.
Log in to DeviceManager at the secondary site, choose Data Protection > Remote
Replication > Remote Replication Consistency Group, and perform the following
operations.
a.
Right-click the consistency group to be split and choose More > Split.
b.
Right-click the consistency group for which you want to disable secondary resource
protection. Choose More > Disable Protection for Secondary Resource to set
secondary LUNs of all remote replication pairs in the consistency group to readable
and writable.
c.
Right-click the consistency group for which you want to perform a primary/
secondary switchover. Choose More > Primary/Secondary Switchover to switch
secondary LUNs of all remote replication pairs in the consistency group to primary
LUNs.
Log in to the standby server at the secondary site and write file Y1.txt to the new primary
LUNs. Check whether the primary LUNs are readable and writable.
– If yes, a primary/secondary switchover can be performed on the secondary site.
– If no, a primary/secondary switchover cannot be performed on the secondary site.
Check whether an alarm about remote replication exists on DeviceManager at the
primary and secondary sites. If yes, solve the fault based on the alarm information
and repeat the previous operations. If no, contact technical support engineers.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Configuring Remote Replication
Provisioning > LUN > LUN Group. Click
70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents