40
F U E L S Y S TE M
TROUBLE-.SHOOTING CHART 3, FUEL SYSTEM
TROUBLE
POS8IBLE CAUSE
REMEDY
I
No gasoline to
carburetor
Vapor lock in fuel line or
I
Allow engine
pump.
, check for possible
over heating.
Defective fuel pump.
I
See Sect 3.Z.3.L
Restricted fuel line.
I
Clean or replace.
Clogged fuel strainer.
I
Clean, Sect 3.2.2 -
adjust service periods
and check source of
contamination.
Flooding
Overchoking.
I
Adjustor repair choke.
Incorrect adjustment of
carburetor float level.
I
See Sect 3.2.5.3.
Electric choke
won't open
Incorrect adjustment -
defective heating elementJ See Sect 3.2.4.
Incorrectly installEd
bi-metal spring.
See Fig 3.2.F.
Binding choke shaft.
Disassemble and
repair.
Excessive Fuel
Consumption
Generator overloaded.
Poor compression.
Reduce load.
See Sect 3. 7.2.
Carburetor out of
adjustment.
Adjust carburetor.
Power Lag When
Metering well vent
Clean carburetor.
Load is Increased
restricted.
Clean extended air pass­
age through air cleaner
adapter and gasket (late
!
models).
;
-,