REVOLVING FIELD GENERATOR
the outer wrapper and laminations. Extend all other leads out of
the generator through the notch in the engine to generator adapter.
7. Install the bearing stop clip on the baUbearing.
8.
Install and secure theendbell. Theballbearing stop clip should fit
into the notch in the ballbearing mount on the endbell.
g. Tighten the thru-rotor-stud nut to 55 to 60 lbs-ft.
10. R econnect the leads to the ignition system and other equipment on
the engine.
11.
Install lead B1 on the adjustable resistor.
CAUTION: Check this lead to see that it is short and keep
it
away
from the blower.
If
necessary when installing a new
stator or leads, cut
it
shorter and reinstall the connec­
tor.
12. Install E1 and E2 on the Magneciter terminals El and E 2 .
1:3. Install the brushes and brush holders.
14. Close the Magneciter, secure with 2capscrewsand install the
end cover.
"