KIESELMANN GmbH Table of contents T a b l e o f c o n t e n t s 1 General informations .............................. 4 Informations for your safety ............................... 4 Marking of security instructions............................ 4 General designated use .............................. 4 Personnel ..................................... 4 Modifications, spare parts, accessories .......................... 5 General instructions ................................ 5...
We will be at your disposal also after expiration of the warranty. In addition, you will also find all necessary instructions and spare part data for maintenance in this instruction manual. If you don't want to carry out the maintenance by yourself, our KIESELMANN GmbH - service team will naturally be at your disposal.
KIESELMANN GmbH | Operating instruction General informations | 1 1.5 Modifications, spare parts, accessories Unauthorized modifications, additions or conversions which affect the safety of the fitting are not permitted. Safety devices must not be bypassed, removed or made inactive. Only use original spare parts and accessories recommended by the manufacturer.
2 | Safety instructions Operating instruction | KIESELMANN GmbH 2 S a f e t y i n s t r u c t i o n s 2.1 Intended use This vakuum valve is used to prevent underpressure in tanks and vessels in plants of the food and drink industry, pharmaceutical and chemical industries as well as in biotechnology.
4 | Function and operation Operating instruction | KIESELMANN GmbH 4 F u n c t i o n a n d o p e r a t i o n 4.1 Description of function The function of the vacuum valve is to prevent inadmissible pressure shortfalls (≤ 1bar absolute pressure), in tanks and containers, which can result in damage.
KIESELMANN GmbH | Operating instruction Function and operation | 4 Lubricant recommendation EPDM; HNBR; NBR; FKM; k-flex - Klüber Paraliq GTE703* Silicone - Klüber Sintheso pro AA2* Thread - Interflon Food* *) It is only permitted to use approved lubricants, if the respective fitting is used for the produc- tion of food or drink.
5 | Technical data Operating instruction | KIESELMANN GmbH 5 T e c h n i c a l d a t a 5.1 Vacuum valve Model: Venting valve • weight-loaded • pneumatically liftable • optionally with heating element, temperature sensor, sensor...
KIESELMANN GmbH | Operating instruction Technical data | 5 5.3 Pneumatic actuator Type 76 Type 104 6162 076 900 – 032 6162 104 900 – 032 Total height 85 mm Total height 97 mm Installation height 67 mm Installation height...
6 | Disassembly and assembly Operating instruction | KIESELMANN GmbH 6 D i s a s s e m b l y a n d a s s e m b l y 6.1 Disassembly NOTICE All threaded joint have right-hand thread.
KIESELMANN GmbH | Operating instruction Disassembly and assembly | 6 Basic valve DN 65- DN 250 Unscrew set screw. Pliers Remove the joint. Joint • DN50 - DN100 Remove circlip ring. Circlip Set screw Housing with splash guard Remove downwards the shaft with plate A and plate B.
7 | Drawings and dimensions Operating instruction | KIESELMANN GmbH 7 D r a w i n g s a n d d i m e n s i o n s 7.1 Drawings Vacuum valve - basic version Housing...
Page 15
KIESELMANN GmbH | Operating instruction Drawings and dimensions | 7 Version with pneumatic lifting device and splash guard 11 10 boltBoldbolt Inner splash guard Allen screw DN65-DN250: Housing with vat DN 50: Vat with O-ring splash guard boltBoldbolt Screw Disc Sensor mounting Pneum.
7 | Drawings and dimensions Operating instruction | KIESELMANN GmbH 7.2 Dimensions Vacuum valve - basic version Dimensions [mm] LK bolt circle 85 x 2,0 115 [4 x M10] 104 x 2,0 130 [4 x M8] 129 x 2,0 160 [4 x M8]...
Page 17
KIESELMANN GmbH | Operating instruction Drawings and dimensions | 7 Version with pneumatic lifting device and splash guard Dimensions [mm] 6164_EN 17 / 21 www.sks-online.com www.sks-webshop.com...
8 | Wearing parts Operating instruction | KIESELMANN GmbH 8 W e a r i n g p a r t s O-ring (4) O-ring (5) 2304 050 050-052 2304 083 050-170 2304 065 050-052 2304 087 050-170 2304 080 050-052...
KIESELMANN GmbH | Operating instruction Characteristic curves | 9 9 C h a r a c t e r i s t i c c u r v e s 9.1 Performance chart NOTICE The flow capacities as well as the characteristic curves refer to the factory setting with a default set pressure of 3 mbar (30 mm WC).
KIESELMANN GmbH | Operating instruction Appendix | 10 1 0 A p p e n d i x 10.1 Declaration of incorporation Declaration of incorporation Translation of the original Manufacturer / authorised representative: KIESELMANN GmbH Paul-Kieselmann-Str. 4-10 75438 Knittlingen Germany...