4. Service Factory Menu
Displaying / Setting Pulse Meter
• A function to display or set the present pulse meter.
• The display is ten million unit
• The setting is hundred billion unit.
• Able to set up using RS-232C command.
Pulse meter display: PMD
Pulse meter setting: PMS+ XXX
Writing setting in EEPROM for Plug & Play use
• Releasing Write-protection of EEPROM for Plug & Play use.
• Able to set only in service factory mode and RS-232C factory
adjustment mode.
When it exits the above modes, it returns to Protect setting.
• Able to set up using RS-232C command.
Write protect release: EWY
Write protect setting: EWN
5. RS-232C
Picture mute ON/OFF setting
• A function to set Picture MUTE on or off.
• No Last Memory function.
• MUTE is canceled when other operations are conducted.
• Able to set using RS-232C command only.
• It is effective in case of only Normal mode/ RS-232C adjustment
mode/ RS-232C factory adjustment mode.
Drive ON / OFF Setting.
• A function to set Drive circuit on or off.
• There is no last memory function. (After turning off a unit, this
setting is canceled)
• Able to set using RS-232C command only.
• The command is effective only in Standby mode and RS-232C
factory adjustment mode.
100 % display mode setting 100%
• A function to change screen display into 100 % display.
• It functions only in case of VIDEO signal.
• All of menu modes are prohibited during this setting.
• Able to set up using RS-232C command only.