5.2 General Section Options

The configuration parameters in the general section of the niacfg.ini file are:

MODE

BIT RATE

IP ADDRESS

NETMASK
GATEWAY
BROADCAST
LEARN
PORT
PAIR
5.2.1 Mode
This parameter is listed as MODE =1 in the factory file. The only available option is 1 for
Peer Routing mode. If this parameter is set to anything but 1 the SEC will not route Peer
messages.
5.2.2 Bit Rate
This parameter is listed as BIT_RATE=38400 in the factory file. It sets the bit rate that the
SEC uses to communicate with the Microlok II unit. The available options for bit rate are:
300, 600, 1200, 2400, 4800, 9600, 19200, 38400. In the absence of a value for this
parameter in the configuration file, the Bit Rate will default to a value of 9600.
The Bit Rate must be set to match the Microlok II application, otherwise it will not
communicate with the Microlok II unit. The Bit Rate is determined by the Applications
personnel.
Copyright 2019
If any of these options are changed in the configuration file
and it is preceded by a # sign, that # sign must be removed.
Otherwise the SEC will not recognize the parameter.
In the factory configuration file there is a TTL parameter.
This parameter is not used. The value of this parameter is
of no meaning to the SEC.
SM6800O Rev. 1, March 2019
®