Installation and Configuration
2B
This section describes the minimum system requirements for installing and configuring an
SEC.
To install the SEC the following equipment is required:
• A PC with Internet Explorer Version 6.0 or higher. (These procedures are written for
Internet Explorer 6, if your PC uses a different version of Internet Explorer; please check
your IT department for any differences in the procedures.)
• A serial cable
• A standard Ethernet cable (for connecting the SEC to an Ethernet network)
• A crossover Ethernet cable (for connecting the SEC to a PC)
• A WAGO power connector (STS supplied)
3.1
Power Source Cable Configuration
10B
Power is supplied through the front mounted WAGO cage clamp style connector. It is
recommended that 14-18AWG wire be used for the power connections. The negative battery is
connected to Pin 1 of the connector and the positive battery is connected to Pin 4 (
Copyright 2019
POWER CONNECTOR
+
Battery Input
9.8VDC - 16.2VDC
-
No keying is required for the power connector
4
3
2
1
WAGO Connector
(J7091461910)

Figure 3-1 - Power and WAGO Connectors

SM6800O Rev. 1, March 2019
®
Microlok II
ORANGE on SEC
4
3
2
1
+
Battery Input
9.8VDC - 16.2VDC
-
Serial-to-Ethernet Converter (SEC)
Figure 3-1
).
X
X
3-1