6. Type (none) after the prompt for your password as follows and press the Enter key:
password: (none)
The system will indicate that you have established an ftp connection with the following
prompt:
ftp>
7. Start ftp binary transfer mode by typing the bin command after the ftp prompt and
pressing the Enter key as follows:
ftp>bin
8. Upload the firmware by typing put and the file name, and pressing the Enter key as
follows:
ftp> put image.bin
While the file is uploading to the SEC, the prompt will disappear. When the upload
process is complete, the ftp> prompt will return as follows:
ftp>
9. When the ftp> prompt returns, end the ftp connection by typing quit and pressing the
Enter key as follows:
ftp>quit
10. The SEC unit will program itself and reboot in approximately 10 seconds.
The green LED on the Digi module (Ethernet Connector) (
it is booting. When it has booted up, the green LED will go out, and the yellow Ethernet
LED will turn off for a brief moment. A few seconds after the yellow LED comes on again,
the SEC is fully running.
When uploading a new firmware or a new configuration file, the SEC may reboot itself
again. After the first boot, the SEC reads the new niacfg.ini file and stores the IP
information into its config area. When it boots the second time, it uses the new IP address
from the config area.
3.11
Identifying IP Addresses of Digi-based Devices on a Network
20B
A utility program is available from Digi to identify the IP addresses and other information for
Digi-based devices on the network. This section describes how to download that utility.
Copyright 2019
Be sure to include the parentheses with the word none.
SM6800O Rev. 1, March 2019
®
Microlok II
Serial-to-Ethernet Converter (SEC)
NOTE
Figure 3-19
X
) will come on while
X
3-19