After the SEC has been rebooted, it will use the new settings, including the IP address you
specified in the edited niacfg.ini file.

Figure 3-19 - Digi Module Front View Showing Yellow and Green LEDs

3.9
SEC Configuration Options
18B
23B
3.9.1
Changing Network Settings
24B
You may need to change network settings in addition to the IP address, such as the netmask
and gateway. These settings are in the [GENERAL] section niacfg.ini file, as shown in
3-20
. This is the same section as the IP address. To access these settings see Section
X
the procedure.
3.10
Uploading new SEC Firmware
19B
The design of the SEC includes a Digi-Connect ME (Micro Embedded) device server. The
server, a file system, and user data are maintained on a flash EPROM that is part of the device
server. From time to time, upgrades to the firmware, the manufacturer's software that
implements the device server and file system, are made available by the manufacturer (Digi
International). These upgrades typically include minor bug fixes and enhancements of features.
Copyright 2019
Changes to the configuration file should be made only with
information supplied by the networking or IT personnel.
[GENERAL]
IP=192.168.1.10
NETMASK=255.255.0.0
GATEWAY=192.168.1.1
DHCP is not supported.

Figure 3-20 - GENERAL Section of the niacfg.ini File

SM6800O Rev. 1, March 2019
®
Microlok II
Serial-to-Ethernet Converter (SEC)
YELLOW LED (LINK STATUS)
GREEN LED
(NETWORK ACTIVITY/DIAGNOSTIC)