Manual EKS Electronic-Key Adapter Ethernet TCP/IP
7 Setup
Perform setup in the following sequence:
1. Set the DIP switches on the Electronic-Key adapter
(see chapter 4.4).
2. Check whether mounting and electrical connection are correct
(see chapter 5 and chapter 6).
3. After connection of the power supply, the LED on the front of the Electronic-Key adapter first illuminates red.
When the connection has been established, the LED illuminates green and signals readiness for operation.
4. Insert Electronic-Key into the Electronic-Key adapter. The LED changes to yellow.
5. Important: for the version EKS FSA, all safety functions must also be thoroughly tested.
7.1
Network settings
You need the following information to integrate the EKS Electronic-Key adapter in the network:
IP address of the host computer with which you want to configure the Electronic-Key adapter.
Free IP address that can be assigned to the EKS Electronic-Key adapter (not needed if the IP address is
obtained automatically from a DHCP server)
Subnet mask of the network in which the Electronic-Key adapter is to be operated
If necessary, information on valid gateway
If necessary, information on valid DNS server
Information!
The TCP connection to the Electronic-Key adapter must be made using port 2444. If the Ethernet
ActiveX
®
module is used, this port is set by default. If the connection is to be made from a control
system, for example, this port must be set explicitly.
7.1.1 Network settings for a configuration PC with Windows
Information!
It is assumed that you connect the PC to the EKS read/write station as shown in the following
example.
For connection, you need a (Cat 5) patch cable.
You must first modify the network settings on the PC so that the web interface can be opened.
Enter IP address for the PC from 192.168.1.2 to 192.168.1.254.
Enter subnet mask for the PC as 255.255.255.0
®
Windows
Figure 3: Connection of configuration PC
2100420-03-05/19
Subject to technical modifications
®