DIP switch settings

The device has three DIP switches (S1, S2, S3).
DIP switch
Function
S1.1 ... S1.4; write and read settings
S1
(4-fold)
S2.1 ... S2.8; setting of a fixed DNS name (required only for special applications)
S2
(8-fold)
S3.1 ...S3.4; settings for network connection and service
S3
(4-fold)
Information!
The settings are adopted only when the power supply is switched on.
4.4.1 DIP switch S1
DIP
Function
switch
S1.1
ON = write protection for Electronic-Key read/write
S1.2
No function
S1.3
No function
S1.4
No function
Information!
It is imperative that all DIP switches without a function (S1.2, S1.3 and S1.4) are set to OFF! In this
way problems with any functions added in the future will be avoided.
4.4.2 DIP switch S2
DNS
LSB
name
S2.1
EKS000
OFF
EKS001
ON
EKS002
OFF
EKS003
ON
...
...
EKS254
OFF
EKS255
ON
Page 14/34
S2.2
S2.3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
...
...
ON
ON
ON
ON
Subject to technical modifications
S2.4
S2.5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
ON
ON
Factory setting
OFF
OFF
OFF
OFF
S2.6
S2.7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
ON
ON
ON
ON
2100420-03-05/19
MSB
S2.8
OFF
OFF
OFF
OFF
...
ON
ON

Hide quick links: