Direct Acting Hydraulic System (D.h.); Control Boxes And Power Supply - Hardi COMMANDER Plus Series Operator's Manual

Table of Contents

Advertisement

irect Acting Hydraulic system (D.H.)
D
(optional)
Installation of control box
1. Connect the plug A to the tractor's 12V power
system. Try to hook up the handle as close as
possible to the battery power supply. HARDI
recommends using an electric distribution box (ref.
no. 817925) to ensure a good power supply to
various 12V attachments.
Note: Check with your dealer or tractor operator's
manual for the best location to hook up the 12V system.
Note polarity: BROWN wire
BLUE wire
2. Route the cable with the 7 pins, from the sprayer's
hydraulic mount plate to the tractor.
3. Mount the hydraulic control box B in a suitable
location in the tractor cabin.
4. Connect the female 7 pin plug C from the switch box
to the 7 pin male plug D from the sprayer.
B
16
Sprayer setup
®
= Positive (+)
= Negative (-)
A
C
D
®
HARDI
COMMANDER

Control boxes and power supply

The control boxes for the ECP operating unit are fitted
in the tractor cabin in a convenient place. Self-tapping
screws can be used for mounting.
Ø4.8 x 9.5mm
Ø4.8 x 12mm
Power requirement is 12V DC.
Note polarity: BROWN wire
BLUE wire
The wires must have a cross sectional area of at least
2
12wg (4 mm
) to ensure sufficient power supply. For
the ECP operating unit the tractor circuit should have
an 8 Amp fuse (5 Amp fuse for hydraulic system).
The 12V power sockets on the control boxes can be
plugged directly into either a HARDI
tion box (#817925) or a single female bayonet style
plug (#260827). Both of these are available from your
HARDI
®
Dealer.
12-volt junction box (#817925) for 12-volt hook-up.
OPERATOR'S MANUAL
= Positive (+)
= Negative (-)
®
4 outlet connec-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commander plus 750Commander plus 1200

Table of Contents