The Soft Heat Server - Bunn Dual SH BrewWISE Technical Training Manual

Dbc system
Table of Contents

Advertisement

®
The Soft Heat
Server
The server stores and dispenses the brewed coffee.
Soft Heat
®
technology allows the coffee to be main-
tained at a set temperature for a set period of time.
These settings are programmed from the factory but
can be adjusted by customer request. The server
features a safety fresh brew thru-lid, regular and decaf
indicator, a faucet guard, and two carrying handles on
the top.
The server contains the holding vessel for the cof-
fee wrapped in dense insulation. In the bottom of the
server is a 72W 24VDC heating element, along with
a control board, thermistor, and electrical contacts so
the server can receive power from the brewer. On the
front of the server there is a red LED that indicates the
server is in contact with the brewer.
The Soft Heat
®
control board contains controls for
temperature and holding time. The holding time is ad-
justed by turning the small white dial. The temperature
can be adjusted by cutting or reconnecting leads to
resistors. Note- the resistor can only be reconnected
by soldering the connections.
Number
Minutes
0
Off
1
30
2
45
3
60
4
90
5
120
6
150
7
180
8
210
9
240
Electrical contacts
Control board
Control Temperature
Shown in ºF
176.0
176.9
177.8
178.7
179.6
180.5
181.4 (Default)
182.3
183.2
184.1
185.0
185.9
186.8
187.7
188.6
189.5
Red LED
Heating element
Jumper Program
Position
I = In
O = Cut
1
2
3
4
I
I
I
O
I
I
O
I
I
I
O
O
I
O
I
I
I
O
I
O
I
O
O
I
I
I
I
I
I
O
O
O
O
I
I
I
O
I
I
O
O
I
O
I
O
I
O
O
O
O
I
I
O
O
I
O
O
O
O
I
O
O
O
O
Bunn-O-Matic Corporation