Parameter assignment/addressing

3.1

Notes on commissioning

Note
Compatibility
The 1PH808x Premium Performance motor can only be operated on SINAMICS controllers
that include the "Higher current controller dynamic response" option.
• Check the availability of the option in accordance with Step 1 of the following sequence of
steps.
1PH8 motors in the "Premium Performance" version are presently not plug & play
components.
Following automatic commissioning you must make additional parameter adaptations. This
also applies to motor versions with DRIVE CLiQ.
A converter setting data sheet is available for every 1PH8 motor in the Premium
Performance version. (See the chapter "Converter data sheets and characteristics")
3.2

Sequence of commissioning steps

The motors are commissioned in 10 steps.
The required setting values can be found in the relevant converter setting data sheet.
Danger to life due to unexpected movements of motors resulting from incorrect
parameterization of the converter
Incorrect or incomplete parameterization of the converter can cause unexpected
movements in the motor and the machine. Unexpected movements can cause death,
severe injury or damage to property.
• Fully parameterize the converter.
• Do not switch the motor on until parameterization has been completed.
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Commissioning Manual, 10/2014, 610.40106.40
WARNING
3