Siemens SIMOTICS M-1PH8 Commissioning Instructions page 27

Premium performance main motors for sinamics s120
Table of Contents

Advertisement

1PH8081-1_U0/1, operation on Booksize Combi with 300% overload
Motor/DRIVE CLiQ data
Rated motor voltage
Rated motor voltage
Rated motor power
Rated motor power factor
Rated motor frequency
Rated motor speed
Motor rated magnetizing current/short-circuit
current
Maximum motor speed
Motor stall torque correction factor
Type of motor cooling
Motor moment of inertia
Motor weight (for thermal motor type)
Speed at the start of field weakening Vdc =
600 V
Motor stator resistance, cold
Cold motor rotor resistance/damper re-
sistance d-axis
Motor stator leakage inductance
Motor rotor leakage inductance/damping
inductance d axis
Motor magnetizing inductance/magnetizing
inductance d axis, saturated
Mot_temp_mod 2/KTY warning threshold
Mot_temp_mod 1/2 threshold
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Commissioning Manual, 10/2014, 610.40106.40
Booksize Combi with 300% overload
400 V
p304
264
p305
12.2
p307
2.8
p308
0.58
p310
302.7
p311
9,000
p320
8.3
p322
24,000
p326
78
p335
1
p341
0.0045
p344
24
p348
p350
0.149
p354
0.095
p356
0.325
p358
0.816
p360
9.000
p604
150
p605
170
Converter data sheets and characteristics
4.1 Forced ventilation
480 V
264
12.2
2.8
0.58
302.7
9,000
8.3
24,000
78
1
0.0045
24
0.149
0.095
0.325
0.816
9.000
150
170
27