Siemens SIMOTICS M-1PH8 Commissioning Instructions page 44

Premium performance main motors for sinamics s120
Table of Contents

Advertisement

Converter data sheets and characteristics
4.1 Forced ventilation
Additional parameterization
Motor type selection
Line resistance
Current controller adaptation, starting point
KP
Current controller adaptation, starting point
KP adapted
Current controller adaptation, P gain adapta-
tion
Current limit
Maximum rotation speed
Torque limit, upper/motoring
Torque limit, lower/regenerative
Power limit, motoring
Power limit, regenerative
Maximum field-generating current
Pulse frequency setpoint
Modulator configuration
Current controller P gain
Reference speed reference frequency
Reference current
Reference torque
Hysteresis speed n_act > n_max
44
Booksize Combi with 300% overload
400 V
p300
p352
0.12
p391
p392
10
p393
50
p640
60
p1082
24,000
p1520
18
p1521
-18
p1530
22.1
p1531
-22.1
p1603
90
p1800
p1810
"&H800"
p1715
3.3
p2000
24,000
p2002
60
p2003
18
p2162
480
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
1
8
8
Commissioning Manual, 10/2014, 610.40106.40
480 V
1
0.12
8
10
50
60
24,000
18
-18
24.1
-24.1
90
8
"&H800"
3.3
24,000
60
18
480