1Ph8087-1_V0_1 (Fp = 8 Khz) - Siemens SIMOTICS M-1PH8 Commissioning Instructions

Premium performance main motors for sinamics s120
Table of Contents

Advertisement

4.1.6

1PH8087-1_V0_1 (fp = 8 kHz)

1PH8087-1_V0/1, operation on Booksize 60 A
Motor/DRIVE CLiQ data
Rated motor voltage
Rated motor voltage
Rated motor power
Rated motor power factor
Rated motor frequency
Rated motor speed
Motor rated magnetizing current/short-circuit
current
Maximum motor speed
Motor stall torque correction factor
Type of motor cooling
Motor moment of inertia
Motor weight (for thermal motor type)
Speed at the start of field weakening Vdc =
600 V
Motor stator resistance, cold
Cold motor rotor resistance/damper re-
sistance d-axis
Motor stator leakage inductance
Motor rotor leakage inductance/damping
inductance d axis
Motor magnetizing inductance/magnetizing
inductance d axis, saturated
Mot_temp_mod 2/KTY warning threshold
Mot_temp_mod 1/2 threshold
Commissioning instructions for SIMOTICS M-1PH8 Premium Performance
Commissioning Manual, 10/2014, 610.40106.40
400 V
p304
296
p305
19.0
p307
6.5
p308
0.72
p310
403.3
p311
12,000
p320
10.6
p322
24,000
p326
70
p335
1
p341
0.0094
p344
37
p348
11,544
p350
0.07727
p354
0.064
p356
0.200
p358
0.499
p360
6.642
p604
150
p605
170
Converter data sheets and characteristics
4.1 Forced ventilation
Booksize 60 A
480 V
296
19.0
6.5
0.72
403.3
12,000
10.6
24,000
70
1
0.0094
37
11,544
0.07727
0.064
0.200
0.499
6.642
150
170
49

Advertisement