3.5.2 EMC Test Results

The following test results have been obtained using a system with a frequency converter (with options if relevant), a screened control cable, a control box
with potentiometer, as well as a motor and motor screened cable.
RFI filter type
Standards and requirements
3
With RFI
AF-650 GP:
No RFI obtain Class A2
AF-650 GP
With RFI
AF-650 GP
No RFI
AF-650 GP
Table 3.1: EMC Test Results (Emission, Immunity)
1) Frame size 2X
2) Frame size 3X
36
EN 55011
Class B
Housing, trades
and light indus-
tries
EN/IEC 61800-3
Category C1
First environ-
ment Home
and office
0-37 kW 200-240 V
50 m
0-75 kW 380-480 V
50 m
0-3.7 kW 200-240 V
No
5.5-37 kW 200-240 V
No
0-7.5 kW 380-480 V
No
11-75 kW 380-480 V
No
90-800 kW 380-480 V
No
90-1000 kW 525-690 V
No
1)
No
11-22 kW 525-690 V
30-75 kW 525-690 V
2)
No
90-800 kW 380-480 V
No
1)
No
11-22 kW 525-690 V
30-75 kW 525-690 V
2)
No
90-315 kW 525-690 V
No
0.75-75 kW 525-600 V
Conducted emission
Class A
Class A Group 2
Group 1
Industrial envi-
Industrial en-
ronment
vironment
Category C2
Category C3
First environ-
Second envi-
ment Home
ronment Indus-
and office
trial
150 m
150 m
150 m
150 m
No
5 m
No
25 m
No
5 m
No
25 m
No
150 m
No
150 m
No
25 m
No
25 m
150 m
150 m
100 m
100 m
150 m
150 m
30 m
150 m
-
-
-
AF-650 GP Design Guide
Radiated emission
Class B
Class A Group 1
Housing, trades
Industrial environ-
and light indus-
ment
tries
Category C1
Category C2
First environment
First environment
Home and office
Home and office
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
Yes
No
Yes
No
No
-
-