4.3 Electrical Data - 380-480 V
Mains Supply 3 x 380 - 480 VAC
AF-650 GP
Typical Shaft Output [kW]
Typical Shaft Output [HP] at 460V
Unit Size IP20/IP21
Unit Size IP55, 66
Output current
Heavy duty (HD) 160% for 1 minute
Shaft output [kW]
Continuous
(3 x 380-440 V) [A]
Intermittent
(3 x 380-440 V) [A]
Continuous
(3 x 441-480 V) [A]
Intermittent
(3 x 441-480 V) [A]
Continuous KVA
(400 V AC) [KVA]
Continuous KVA
(460 V AC) [KVA]
Max. cable size
(mains, motor, brake)
[AWG]
2)
Max. input current
Continuous
(3 x 380-440 V ) [A]
Intermittent
(3 x 380-440 V ) [A]
Continuous
(3 x 441-480 V) [A]
Intermittent
(3 x 441-480 V) [A]
Max. mains fuses
Environment
Estimated power loss
at rated max. load [W]
Weight,
Unit Size IP20
Unit Size IP55, 66
Efficiency
0.37 - 7.5 kW only available as 160% heavy duty (HD).
0.37
0.5
12
15
0.37
1.3
2.1
1.2
1.9
0.9
0.9
[mm
2
]
1.2
1.9
1.0
1.6
1)
[A]
10
35
4)
4.7
13.5
4)
0.93
0.75
1.5
2.2
3
1.0
2.0
3.0
4.0
12
12
12
12
15
15
15
15
0.75
1.5
2.2
3
2.4
4.1
5.6
7.2
3.8
6.6
9.0
11.5
2.1
3.4
4.8
6.3
3.4
5.4
7.7
10.1
1.7
2.8
3.9
5.0
1.7
2.7
3.8
5.0
24 - 10 AWG
2
0.2 - 4 mm
2.2
3.7
5.0
6.5
3.5
5.9
8.0
10.4
1.9
3.1
4.3
5.7
3.0
5.0
6.9
9.1
10
10
20
20
46
62
88
116
4.8
4.9
4.9
4.9
13.5
13.5
13.5
13.5
0.96
0.97
0.97
0.97
AF-650 GP Design Guide
4
5.5
7.5
5.0
7.5
10
12
13
13
15
15
15
4
5.5
7.5
10
13
16
16
20.8
25.6
8.2
11
14.5
13.1
17.6
23.2
6.9
9.0
11.0
6.5
8.8
11.6
24 - 10 AWG
2
0.2 - 4 mm
9.0
11.7
14.4
14.4
18.7
23.0
7.4
9.9
13.0
11.8
15.8
20.8
20
32
32
124
187
255
4.9
6.6
6.6
13.5
14.2
14.2
0.97
0.97
0.97