11.12.8 Cross traffic
1
1
1
1
1
1
All logics except for the logic PB in direction 1 supply in this traffic situation miscounts since they
count on instead of off signals!
11.12.9 Direction Logics "Parking Bay"
This direction logic is used for short entries and exits. The impairment of the counting process by cross traffic
on loop 1 is suppressed in this logic. It is irrelevant whether loop 1 is placed into the through road or in the
maneuvering area.
Durchfahrt
Through road
(Straße)
1
2
The placement of loops depends on the direction to be expected for start-stop situations. In traveling di-
rection 1 → 2 no tailback may occur! In the direction of travel 2 → 1, vehicles are also counted correctly
in start-stop situations, but it is necessary that the vehicle gap release one loop respectively.
24
D2
D1
on
2
on
|
2
|
|
off
2
|
|
|
on
2
|
|
off
2
off
2
Parking space
Parkraum
or
09/2015
DB
F1
F2
FE
on
|
|
|
|
|
|
Imp Imp
|
|
|
|
|
Imp
|
|
|
|
|
|
|
|
|
|
|
|
|
___
off
Imp
Durchfahrt
(Straße)
VEK MNE1 / VEK MNE2
PB
SF
BS
Ri1 Ri2
Imp
Imp
___
Imp
Parkraum