11.8 Loop/Output Assignment

Each output may be assigned to a loop channel or, when the direction detection is activated, a specific direc-
tion.
DIP
USB
None
1
Channel 1
1
Channel 2
2
Direction A
2
Direction B
Direction A&B
1
Valid only for presence detection with the direction detection switched off!
2
Valid only when direction detection was activated!
The assignment of the loop channels to the hardware outputs can only be changed via the service pro-
gram!

11.9 Pulse Timing Edge

The following signal shapes may be selected for the outputs if you have set the outputs to pulse output. :
DIP
USB
OFF
Entry
When covering the loop (factory defaults)
ON
Leave
When the loop is free
The default setting for the pulse duration is 200 ms. It can be changed in 100 ms steps in the service
program Detector Tool.

11.10 Timing of Output Signals (On Delay, Off Delay, min. Duration)

The timing properties of the output signals can only be changed with the service program!
For the hardware-based output signals the on delay, minimum duration and the off delay can be adjusted
over the range 0-25500 ms in 100 ms steps.
Factory defaults:
Loop coverage
Output signal
t
:
On Delay
on
t
:
Off Delay
off
t
:
Min. Duration
dmin
t
:
Signal duration
d
If the loop is free before the ON delay has expired, there is no signal output!
18
No loop channel or direction has been assigned or output inactive
Loop channel 1 assigned
Loop channel 2 assigned
Output controlled by direction of travel A
Output controlled by direction of travel B
2
Output is controlled for both directions
On Delay
Off Delay
min. Duration
≥ t
t
t
on
d
dmin
09/2015
Assignment of Hardware Output
(Factory default for output 1)
(Factory default for output 2)
Pulse output
0 ms
0 ms
200 ms
t
off
VEK MNE1 / VEK MNE2
(Factory default for output 1)
(Factory default for output 2)
FEIG ELECTRONIC GmbH