Limit Output; Pin Connections; Data Output Example; Connector Type - norbar Pro-Test 60 SERIES 2 Operator's Manual

Professional torque tester for use with pro-test’s fitted with version 37701.305 software
Table of Contents

Advertisement

Limit Output

The serial port will output LO / OK / HI before the torque value when the limits are being used.
Some software, including the Norbar 'Torque Wrench Calibration Software' (Part 37705.XXX), will not accept
LO / OK / HI characters.
The following table gives all options for the FIRST CHARACTER setting and the OUTPUT LIMITS setting:
First
Character
-
+ & -
NONE

Pin Connections

Data Output Example

Code : DP=Decimal Point.
Pro-Test with the serial port set to the factory defaults. Reading 1068.4 lbf∙ft (clockwise):
1
0
6
8

Connector Type

9 way male 'D' type connector.

Connecting Lead

A 9 way female to 9 way female null modem connecting cable is included with the Pro-Test for connection to
PC's with a 9 way male connector. Alternatively use the Serial Data Lead Kit (part number 60248).
Direction
Output Limits = NO
Clockwise
Anti Clockwise
Clockwise
Anti Clockwise
Clockwise
Anti Clockwise
Pin No
Function
1
Not Connected.
2
Received data (to Pro-Test).
3
Transmitted data (from Pro-Test).
4
Not Connected.
5
Signal ground 0V.
6
Not Connected.
7
Not Connected.
8
Not Connected.
9
Not Connected.
CR=Carriage Return.
DP
4
SP
l
Limits Disabled
1.0335 N∙m
-1.0335 N∙m
+1.0335 N∙m
-1.0335 N∙m
1.0335 N∙m
1.0335 N∙m
SP=Space.
b
f
DP
f
Limits Enabled
Output Limits = YES
LO 1.0335 N∙m
LO -1.0335 N∙m
LO +1.0335 N∙m
LO -1.0335 N∙m
LO 1.0335 N∙m
LO 1.0335 N∙m
t
CR
13