Installing
The following instructions assume you have already installed your Hydrawise controller.
1. Flow meter body: The flow meter has a marking on the body indicating the direction of water flow. Installation
of the flow meter must be in the correct orientation with water flowing in the direction of the arrow on the flow
meter body. All HC Flow Meters must be installed horizontally with the dial facing upward.
MINIMUM
of 10 times
pipe diameter
CONNECT
wires to Hydrawise
controller
HC FLOW METER
Watertight
MINIMUM
connections
of 5 times
pipe diameter
Flow direction
to valves
!