Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
extranet (authentication required).
Online tools
In addition to the documentation set, some online tools are available
for installers.
▪ Heating Solutions Navigator
▪ Digital toolbox that offers a variety of tools to facilitate the
installation and configuration of heating systems.
▪ To access Heating Solutions Navigator, registration to the
Stand By Me platform is required. For more information, see
https://professional.standbyme.daikin.eu/.
▪ Daikin e-Care
▪ Mobile app for installers and service technicians that allows you
to register, configure and troubleshoot heating systems.
▪ The mobile app can be downloaded for iOS and Android
devices using the QR codes below. Registration to the Stand
By Me platform is required to access the app.
App Store
Google Play
2

About the box

2.1

Indoor unit

2.1.1
To remove the accessories from the
indoor unit
a
e
h
a
Shut-off valve with integrated filter
b
Safety valve (connection parts for mounting on top of brine
level vessel included)
c
Brine level vessel
d
Remote outdoor sensor (with installation manual)
e
Cable for remote outdoor sensor (40 m)
EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569811-1 – 2019.02
b
c
d
f
g
ENERG
ENERG
Y
IJA
Y
IJA
IE
IA
IE
IA
i
j
k
f
O-rings (spares for hydro module shut-off valves)
g
Energy label
h
General safety precautions
i
Addendum book for optional equipment
j
Installation manual
k
Operation manual
2.1.2

To handle the indoor unit

Mind the following guidelines when handling the unit:
>200
kg
▪ The unit is heavy. At least 2 persons are needed to handle it.
▪ Use a trolley to transport the unit. Make sure to use a trolley with a
sufficiently long horizontal ledge, suitable for transportation of
heavy appliances.
▪ When transporting the unit, keep the unit straight.
▪ Use the handles at the back to carry the unit.
▪ Remove the hydro module when you want to carry the unit up or
down staircases. See
"3.2.2 To remove the hydro module from the
unit" on page 7
for more information.
▪ It is recommended to use lifting straps to carry the unit up or down
staircases.
3

Unit installation

3.1

Preparing the installation site

3.1.1
Installation site requirements of the
indoor unit
▪ Mind the following spacing installation guidelines:
≥500
≥600
INFORMATION
If you have limited installation space and need to install the
option kit EKGSPOWCAB (=  power cable for split power
supply), remove the left side panel before installing the unit
in its final position. See
page 6.
▪ The indoor unit is designed for indoor installation only and for
ambient temperatures ranging from 5~35°C.
2 About the box
(mm)
"3.2.1 To open the indoor unit" on
Installation manual
5