Sony HDW-S280 Operation Manual page 70

Hd digital videocassette recorder
Hide thumbs Also See for HDW-S280:
Table of Contents

Advertisement

Item
Item name
number
a)
VITC POSITION SEL-1
601
a)
VITC POSITION SEL-2
602
603
ID CODE PRESET
604
ID CODE SW
605
TCG REGEN MODE
606
TC OUTPUT SIGNAL IN
REGEN MODE
607
U-BIT BINARY GROUP
FLAG
70
Items in the Extended Setup Menu
Items 600 to 699: Settings for a timecode generator
Settings
In 59.94i/29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to [16H] to 20H: Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
In 50i/25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to [19H] to 22H: Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
In 59.94i/29.97PsF mode
Select a line to insert the VITC in. (For SD output)
12H to [18H] to 20H: Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
In 50i/25PsF mode
Select a line to insert the VITC in. (For SD output)
9H to [21H] to 22H: Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both items
601 and 602.
Select whether or not to set the ID code.
[OFF]: Do not set the ID code.
ON: Set the ID code.
To set the ID code:
Display this item in the display window, and press the SET function button. The ID code
setting mode is obtained. Select the digit to be set by pressing the T or t function
button. When you select all digits, set the SET function button again. The ID code is
stored and the ID code setting mode is terminated.
Select whether or not to record the ID code set using item 603 in the user bits.
[OFF]: Record the normal data in the user bits.
ON: Record the ID code in the user bits.
Select the signal to be regenerated when the timecode generator is in the regeneration
mode (when the PRST/RGN on the P4 TC page of the function menu is set to LTC or
VITC).
[TC&UB]: Both the timecode and user bits are regenerated.
TC: Only the timecode is regenerated.
UB: Only the user bits are regenerated.
Select the signal output from the TIME CODE OUT connector during normal (x1) speed
playback.
[TAPE]: During tape playback, the playback timecode signal is output without
regeneration.
REGEN: The playback timecode is output after regeneration.
Select the user bits to be used in the timecode generated by the timecode generator.
[000]: Character set not specified
001: 8-bit characters compliant with ISO 646 and ISO 2022
010: Undefined
011: Undefined
100: Undefined
101: SMPTE 262M page/line multiplex system
110: Undefined
111: Undefined

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents