Cleaning, replacing and resealing the quartz tube
Hide thumbs Also See for Ultra UV2:

Advertisement

CONSUMER OPERATING
INSTRUCTIONS
QUARTZ TUBE MAINTENANCE
NOTICE
Inspect the Ultra UV2 unit for damage, paying close
attention to the quartz tube. If the quartz tube is broken/
cracked contact the manufacturer for replacement.
Cleaning the quartz tube: The quartz tube requires cleaning
every 6 months to ensure optimum performance.
1. Turn off all power to the ULTRA UV2 unit and all
other pool equipment. Unplug the unit from its
power receptacle or turn OFF the circuit breaker
that is the ULTRA UV2's power source. Before
proceeding to step 2 allow at least 15 minutes for
the lamp(s) in the unit to cool.
DANGER
disconnecting the power (power source) for the Ultra
UV2 unit. Never remove the Ultra UV2 unit's cover
without turning off the pump.
2. Remove the three screws that secure the plastic
cover then remove Fig. 1.
WARNING
gloves and safety eye wear. Do not handle a hot lamp
or serious burns will occur.
NOTICE
create hot spots & greatly shorten lamp life.
3. Disconnect all lamps by pressing the release tabs
on connectors and gently pulling apart. Fig. 8
4. Remove the spring clip Fig. 9. Carefully lift the old
lamp assembly, including lamp holder, from the
quartz tube Fig. 10. Do not pull excessively on the
lamp wires. Set aside the lamp assembly in a safe
area to avoid breaking or chipping.
5. Turning counter-clockwise, unscrew and remove
the round aluminum sealing nut. Fig. 11
6. Carefully lift the aluminum compression washer
from the top of the quartz tube making sure not to
lose the black gasket that cushions the edge of the
quartz tube. Fig. 12
FIRST STEP IN
STARTING YOUR
INSTALLATION
Never remove the
electrical enclosure
cover without first
Before removing
lamps you must wear
protective rubber
Do not touch the
glass part of the
lamp as body oils will
3
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12