Set Mode to "Not Used" When Default Input # & Output # Row Don't Apply

Steps to Assign Inputs to Outputs and Set Modes

1.
Select the Rules tab.
If you are at the Client main screen, select the Site Management button >
Hardware Setup > select the site if you have multiple sites > double click on the
control unit that is connected to the IOCB1616 in the All Hardware screen >
select the IOCB1616 tab > select the Rules tab.
2.
Click on the row with the first applicable primary input to be assigned to an output.
The row is highlighted in blue.
3.
On the input row highlighted in blue, double click under the Operator column, and
choose the desired operator – AND, OR, or RTE – from the drop down list.
If assigning just a single input to a single output, leave the setting on Not Used.
If you make an error or need to clear the assignment, select Clear Operator and
Secondary Input.
4.
Under the Secondary Input column, double click on the highlighted row, and choose
the desired secondary input from the drop down list.
5.
If you are not assigning a secondary input, leave the field blank.
6.
Under the Output column, double click on the highlighted row, and choose the desired
output from the drop down list.
7.
Under the Mode column, double click on the highlighted row, and choose the desired
mode from the drop down list.
8.
Repeat setting inputs, operators, outputs, and modes. When you have completed
assigning inputs to outputs, click on the Save button.
9.
If you have additional IOCB1616 boards connected to other access control units,
repeat all the above procedures to define and assign the inputs and the outputs;
otherwise click on the Back button until you are returned to the main screen or the
Navigation History button for a previously viewed screen.