Software Setup; Steps To Create Input Names And Specify Input Timers - Keyscan Aurora IOCB1616 Installation Manual

Table of Contents

Advertisement

Software Setup

The following sections outline procedures to setup the IOCB1616 in the Client module. We
suggest you review the J17 - IOCB1616 Address Chart in the Hardware section to ensure
that the input/output assignments defined in the software match the addresses specified
by the J17 jumper setting on the IOCB1616 circuit board.

Steps to Create Input Names and Specify Input Timers

These instructions assume you have previously enrolled the access control unit connected
to the IOCB1616 circuit board.
1.
From the Client main screen, select the Site Management button > Hardware Setup.
If you have multiple sites, double click on the site in the Hardware Setup
directory screen.
2.
From the Hardware Setup screen, double click on the control unit that is connected to
the IOCB1616 in the All Hardware screen.
3.
Select the IOCB1616 tab.
4.
Double click on the IOCB Input # 1 or the first input point to be named.
5.
In the text box, enter a name or description appropriate for the input point.
6.
If applying Delayed Output, Timed Output or Pulsed Output operating mode for this
input leave the Input Timer setting as is and go to the next step, otherwise double
click on the input row under the Timer column, and select a delay time from the drop
down list.
7.
Repeat the preceding steps to add additional input points or continue to the next step
if you have completed naming inputs.
8.
Click on the Save button.
9.
To add outputs follow the steps listed under Steps to Create Output Names and
Specify Output Timers.
IOCB1616 Installation Guide (Aurora 06.15)