Assigning Inputs to Outputs

There are 2 conventions to be aware of before assigning inputs to outputs:
The default IOCB1616 Rules screen assigns Input #1 with Output #1, Input #2 with
Output #2 etc, in numerical sequence to Input #64 to Output #64 as shown in the
example.
Default IOCB1616 Rules Screen with Matching Input# to Output#
Mode – Not Used
In cases where secondary inputs are used with operators and the row with the default
Input #/Output# is not applicable, set the Mode column for that row to Not Used.
The following table illustrates an example where the default Input#3 is not assigned to
Output #3. You will note that the default row has the Mode set on Not Used.
Primary
Input
IOCB Input #1
IOCB Input #2
IOCB Input #3
IOCB Input #4
The screen capture on the following page depicts how this appears in the Hardware Setup
> IOCB1616 Rules screen.
IOCB1616 Installation Guide (Aurora 06.15)
Operator
Or
Or
Not Used
Or
Secondary
Input
IOCB Input #3
IOCB Input #3
Not Used
IOCB Input #5
Output
Output #1
Output #2
Output #3
Output #3
Mode
Delayed Output
Delayed Output
Not Used
Delayed Output
7