Iocb1616 Power Supply Connections (No Ocb-8S) - Keyscan Aurora IOCB1616 Installation Manual

Table of Contents

Advertisement

IOCB1616 Power Supply Connections (no OCB-8s)

ACU 16V 40VA
or
ACU 16.5V 37VA
Transformer
Primary
110 VAC
KI-00391E-10-11
IOCB1616 Installation Guide (Aurora 06.15)
DPS-15
Terminals
AUX/RDR
BATT
-
+
AC
AC
-
12V
Battery
(-)
Red Power (+)
Connect to
separate
+
12VDC lock
power supply
Notes on IOCB1616
- Lock power and ACU
power must be separate
supplies.
- Current consumption
without low current open
collector connected to any
device draws 100mA
(-)
Red Power (+)
Connect to
separate
+
12VDC lock
power supply
AUX/RDR
EGND
FAIL -
+
+
RX
TX
GND
12V
+
AUX
Power
RX
TX
GND
12V
+
AUX
Power
ACU
-
+
FAIL
ACU Ground
IOCB1616
Circuit Board
IOCB1616
Circuit Board
Lug