Advertisement

Quick Links

Air/Q
565
User Guide
Original Instructions
Updated 15 Jan., 2013

Advertisement

Table of Contents
loading

Summary of Contents for Prolitec Air/Q 565

  • Page 1 Air/Q ™ User Guide Original Instructions Updated 15 Jan., 2013...
  • Page 2 WARNING Read complete installation instructions. 120/220 volts may cause serious injury from electrical shock. Disconnect electrical power before hardwiring an Air/Q. Sharp edges may cause serious injury from cuts. Use care when cutting openings and handling ductwork. CAUTION Do not set scent level to maximum setting or higher than recommended in the table on page 5.
  • Page 3: Table Of Contents

    Table of Contents About Air/Q 565 ......................... 2 ™ Applications ......................... 3 Estimating Cartridge Life ..................... 5 Unpacking ........................... 6 Installation ........................... 8 Starting Up ........................18 Features and Controls ....................18 Installing the Cartridge ....................19 Programming the Appliance ..................20 Setting Scent Intensity ....................
  • Page 4: About Air/Q ™ 565

    The Air/Q 565 is the greenest, most eco-friendly way to introduce scent into an interior space with no negative impact on indoor air quality. This is not an accident.
  • Page 5: Applications

    Air/Q 565 computer-controlled delivery system. Ambient Scenting Ambient Scenting is the use of the Air/Q 565 to enhance the ambience of a space- with a uniformly distributed favorite fragrance. The Air/Q 565 serves as a cost-effective and eco-friendly replacement for wall plug- ins, aerosols, soot-producing scented candles, and other low-performance means of introducing scent in a space.
  • Page 6 One of the most challenging problems in indoor air quality is bad odors. Bad- smelling places have a negative emotional impact on everyone in the space and give a bad impression of the perceived cleanliness of the space. All Air/Q 565 scents contain odor neutralizing ingredients.
  • Page 7: Estimating Cartridge Life

    Air/Q™ 565s needed for a space. Please refer to Pro- litec’s ‘Sizing and Consumption Tool’ which is available from Prolitec in an electronic file. The chart below can be used as a rough guideline for sizing.
  • Page 8: Unpacking

    Unpacking Remove all parts from the container. The following items should be included: 1. The Air/Q Appliance 2. 110/220V to 12V power adapter 3. Universal Adapter Kit 4. Airflow Switch 5. Airflow Switch cable 6. Two (2) Airflow Switch mounting screws 7.
  • Page 9 Unpacking 1. Air/Q 565 Appliance (Not Pictured)
  • Page 10: Installation

    1 foot. D. Positioning the Air/Q 565 Machine: The Air/Q 565 machine is mounted on a flat vertical surface — either a wall or on an air duct. The maximum run of the silicon injector hose between the Cartridge and the Injector Tube is 18”.
  • Page 11 Installation Injector Tube (Pointing with flow) Silicone Injector Hose Air/Q 565 Appliance Airflow Switch Cable Airflow Switch Silicone Air Sensor Hose Sensor Tube (Pointing against flow)
  • Page 12 E. Wall Mounting or Duct Mounting the Air/Q 565 Machine Step 1 — Mounting Kit, Parts and Tools The mounting kit provided with the Air/Q 565 (see details on Page 6) includes a mounting plate, which holds the appliance to the wall or duct surface; 4 screws and wall anchors suitable for attaching the mounting plate to drywall and 4 sheet-metal screws suitable for attaching the mounting plate to ductwork;...
  • Page 13 Installation Step 2 — Marking the Top Anchor Holes Place the mounting bracket at the desired position. Use the level to make sure the mounting bracket is horizontal. While holding the bracket level, use a pointy tool such as a screwdriver or pen to mark the location of the top two holes. Check again with the level to ensure the bracket is horizontal.
  • Page 14 Installation Step 4 — Marking the Bottom Anchor Holes Now you can mark the bottom holes using the mounting bracket as a template. Hold the mounting bracket in place and screw the flat-head screws half way into the top anchors. This will prevent the bracket from moving. Now use the pen or pointy tool to mark the location for the two bottom holes.
  • Page 15 Installation Step 7 — Power Supply Plug the power adapter into the back of the machine. Step 8 — Fitting the Appliance into Place Place the appliance so that the big holes in the top of the back cover fit over the rounded locking posts.
  • Page 16 Installation Step 9 – Securing the Appliance Open the door and insert the 2 long, round- head screws through the holes in the lower corners of the appliance. Tighten the screws firmly. Step 10 — Removing the Yellow Tab Now take the appliance and pull out the yellow tab at the bottom.
  • Page 17 Installation Step 12 — Installing and Connecting the Injection Tube 1. Position the location of the injection tube less than 1 foot above the appliance. 2. Drill a 5/8” hole in the air duct using a step drill less than 1foot above or downstream from the appliance.
  • Page 18 Installation 4. Insert and direct metal injection tube with the air flow. 5. Attach silicone hose to metal injection tube. 6. Insert clear tube into free end of silicone hose. Step 13 — Installing the Sensor Tube 1. Position the location of the sensor tube less than 1 foot away from the airflow switch.
  • Page 19 Installation 3. Fully insert grommet into hole. 4. Insert and direct metal sensor tube against air flow. 5. Attach end of second silicone hose to metal sensor tube. 6. Attach the other end of silicone hose to airflow switch. 7. Connect airflow switch to appliance using the cable provided.
  • Page 20: Starting Up

    Starting Up Air/Q 565 Features and Controls Output Port Lock Air Stem Programming Panel Fragrance Cartridge...
  • Page 21: Installing The Cartridge

    Starting Up Installing the Cartridge 1. Prepare cartridge by removing the top and rear plugs. Do not remove front plug. Top Output Plug Front Output Plug (leave as is) Rear Plug 2. Place the cartridge onto the white air stem. 3.
  • Page 22: Programming The Appliance

    Starting Up Programming the Appliance 1. Unlock and open the door. 2. Turn on the power by pressing the ON/OFF button in the upper left corner of the control panel. 3. Set the Clock. • T urn the dial to Set Clock. The day-of-the-week icon will blink. • A djust the day forward or backward using the + /– buttons on the right side of the control panel.
  • Page 23 Starting Up • N ow the “1” icon is turned on to indicate you are setting program 1. The Rate digits blink to prompt you to set the rate. You may set to any value between 1 and 50, or set to 0 to disable the program. Press the Set button to advance. • I f you set the rate to 0, then the current and subsequent programs are all disabled.
  • Page 24: Setting Scent Intensity

    Starting Up Setting Scent Intensity 1. Consult the Settings Table of Page 5, which provides a setting for the size in cubic feet (length x width x ceiling height) of the space you are treating. Use the indicated intensity setting as a starting point from which you can increase or decrease to taste.
  • Page 25 Maintenance 2. Turn off the power by pressing the power button in the upper left corner. The blue light will go off. 3. Remove the plastic tubing from the Top Output Port. 4. Insert the short section of the removal tool in behind the top section of the cartridge.
  • Page 26: General Care

    ™ signed for use on tabletops or shelves. • NEVER put your nose to the output of the Air/Q 565, or within 12 inches of the output while it is operating. The output of the Air/Q 565 is highly concentrated until it mixes with the airflow of the heating, ventilation and air conditioning sys- tem.
  • Page 27 5 minutes. If there is any eye irritation, consult a physician immediately. • DO NOT drop a cartridge. It may crack, causing fragrance to spill. • For online safety instructions, visit www.prolitec.com/manuals/manuals.htm...
  • Page 28: Frequently Asked Questions (Faqs)

    Air/Q 565 droplets are not only small, they are also very light. What size space will Air/Q 565 handle? The Air/Q 565 has a single-board computer that allows the user to adjust for differ- ent size spaces. With a monthly cartridge change, the Air/Q 565 can handle spaces up to 40,000 cubic feet ( a 4,000 square foot space with 10 foot ceilings) if oper- ated 12 hours a day.
  • Page 29 Frequently Asked Questions (FAQs) How strong should I make the scent? Less is more. Air/Q 565 allows you to erase odors and use only a small amount of scent. Unlike most other air fresheners, Air/Q 565 is adjustable. Use this important feature.
  • Page 30 No problem. There is a single button just below the On/Off switch that you can press to turn the Air/Q 565 ON for a set number of hours. Press the button succes- sively 1 time for each hour of operation. You can set the number of hours you wish.
  • Page 31: Troubleshooting

    Air/Q 565 does not emit a plume Check program period or rotate knob to 24/7 position, then press + button to level 50. Verify that the pump inside Air/Q 565 is running (light appliance vibrations). Check pluming after disconnecting the injector hose from the cartridge.
  • Page 32 Troubleshooting SYMPTOM TROUBLESHOOTING PROCEDURE Air/Q 565 airflow switch not work- Set program to 24/7 and increase dif- fusion rate by pressing the + button to level 50. Make sure furnace blower is operating Verify that the airflow switch is correctly located on the blowing side of the fur- nace, and not on the return air section.
  • Page 33: Specifications

    Specifications Dimensions: Air/Q 565 Appliance 8 " x 8 " x 3 " (21.9 cm x 22.2 cm x 9.8 cm) Weight: 4.7 lbs (2.2 kg) with full cartridge Power Supply: Input — 100 – 240V AC at 0.6A Frequency — 50/60 Hz Protection —...
  • Page 34 Prolitec, Incorporated 1235 W. Canal Street Milwaukee, WI 53223 1-866-387-4333 www.airq.com...