Leuze electronic MSI-MD-FBX Original Operating Instructions page 37

Muting controller
Table of Contents

Advertisement

Error
E10, E11
E14
E15
E16
E18
E19
E39
E40
E42
E80
E87
E89
E97
U10
U30
U31
U32
U33
U34
Leuze electronic
Cause/description
OSSD error, source unknown
Undervoltage (< +16 V)
Overvoltage (> +31 V)
Overvoltage (> +40 V)
Ambient temperature too high
(> 90°)
Ambient temperature too low
(< -35°)
Actuation duration for the ac-
knowledgment unit exceeded
(local socket)
Actuation duration for the ac-
knowledgment unit exceeded
(cabinet socket)
Muting enable signal on +24 V
for too long
Invalid operating mode
Operating mode changed
Switch position of the DIP
switch blocks changed during
operation.
Linkage of electronic safety-re-
lated switching outputs:
OSSDs did not switch simulta-
neously
Invalid command received via
the interface
Sequence error between mut-
ing sensor 1 and muting sen-
sor 2
Sequence error between mut-
ing sensor 2 and muting sen-
sor 3
Sequence error between mut-
ing sensor 3 and muting sen-
sor 4
Sequence error if all muting
sensors are activated and mut-
ing sensor 1 should be free
Sequence error if muting sen-
sors 2 to 4 are activated and
muting sensor 2 should be free
Remedies and measures
Check the wiring. Exchange the
cable and the receiver if neces-
sary.
Supply the device with the correct
voltage.
Supply the device with the correct
voltage.
Supply the device with the correct
voltage.
Ensure correct environmental con-
ditions
Ensure correct environmental con-
ditions
Press the acknowledgment unit. If
the restart is unsuccessful, check
the wiring of the reset button.
Press the acknowledgment unit. If
restart is unsuccessful, check the
wiring.
Check the actuation of the muting
enable signal
Check the configuration of the op-
erating mode and restart.
Check the configuration of the op-
erating mode and restart.
Check the configuration of the op-
erating mode and restart.
Check the wiring.
Check the connection
to the USB interface
Check the arrangement and align-
ment of the muting sensors.
Check the arrangement and align-
ment of the muting sensors
Check the arrangement and align-
ment of the muting sensors
Check the arrangement and align-
ment of the muting sensors
Check the arrangement and align-
ment of the muting sensors
MSI-MD-FBX
Diagnostics and troubleshooting
Behavior of the
muting controller
Automatic reset
Automatic reset
Automatic reset
Locking
Automatic reset
Automatic reset
Automatic reset
Automatic reset
Acknowledgment
unit
Locking
Locking
Locking
Locking
Automatic reset
Automatic reset
Automatic reset
Automatic reset
Automatic reset
Automatic reset
37