Restart

Following a violation of the protective field, the OSSDs are re-enabled via the reset signal.
• The restart can be started manually via the connected acknowledgment unit or via a component in the
control (Starting up the device - Configuration).
• The reset signal can be set via the connected acknowledgment unit or via a component in the machine
interface.
• Duration of the reset signal: 0.2 s to 4 s
4.5

Acknowledging/resetting

The ReadyForReset signal signals via the RES LED that the system is waiting for actuation of the acknowl-
edgment unit/reset button.
• The RES LED illuminates red if the OSSDs of the safety sensor are switched on and
the OSSDs of the muting controller are switched off.
• The RES LED flashes red if the system is expecting a muting restart, depending on the status of the
muting sensors. The OSSDs of the safety sensor must be switched off.
• The RES LED flashes red if a muting error occurs.
• If a muting error occurs together with a protected field violation, the OSSDs are switched off when
muting is terminated.
• If a muting error occurs in a free protective field, the OSSDs remain switched on.