Leuze electronic MSI-MD-FBX Original Operating Instructions page 26

Muting controller
Table of Contents

Advertisement

1
1
Mounting eyes for M4 screws
2
Cover for the DIP switch blocks for configuring the muting function and the Micro USB connection for reading
out diagnostics.
3
7‑segment display
4
Connection to the machine interface (OSSDs and supply voltage)
5
Connection for the safety sensor
6
Connection for external muting indicator
7
Connection for acknowledgment unit
8
Connections for muting sensors
Fig. 7.1:
Muting controller connections
Ä Connect the muting controller to the machine interface (see chapter 7.2 "Pin assignment of the ma-
chine interface").
Ä Connect the safety sensor to the muting controller (see chapter 7.3 "Pin assignment of safety sensor").
Ä Connect the acknowledgment unit to the muting controller (see chapter 7.4 "Pin assignment of the ac-
knowledgment unit").
Ä If necessary, connect the external muting indicator to the muting controller (see chapter 7.5 "Pin as-
signment of muting indicator").
Ä Connect the muting sensors to the muting controller (see chapter 7.6 "Pin assignment of muting sen-
sors").
Leuze electronic
2
3
4
6
MSI-MD-FBX
5
7
8
Electrical connection
26