Connection Technology - Leuze electronic MSI-MD-FBX Original Operating Instructions

Muting controller
Table of Contents

Advertisement

Fig. 3.2:
LED indicators of the muting controller
LED
1
PWR
2
OSSD
3
RI
4
ERR
5
SC
6
7
LC/LG
8
ML
9
RES
10
11
MS1 ... MS4
3.3

Connection technology

NOTICE
Sockets and connectors that are not connected are to be covered with end caps!
Ä Cover unconnected sockets and connectors with end caps.
Leuze electronic
Color
Description
Green
Power (PWR)
Red
OSSDs in the OFF state
Green
OSSDs in the ON state
Yellow
Restart active
Safety sensor on
The system is waiting for actuation of the acknowledgment unit
Red
Fault
Green
Muting sensor alternative active
White
Muting signal from the machine interface active
OFF
OSSDs of the safety sensor in the OFF state
Green
OSSDs of the safety sensor in the ON state
Blue
Muting indicators:
• OFF: no muting active
• Continuous light: muting active; safety sensor is bypassed by
means of muting
• Flashing: muting error; e.g., timeout
Yellow
Acknowledgment unit pressed (reset signal)
Red
Ready for reset (ReadyForReset signal)
The system is waiting for actuation of the acknowledgment unit
Green
Muting sensor 1 ... 4 active