Advertisement

Quick Links

The power behind competitiveness
DELTA BX_6.0 Battery Pack
Operation and Installation Manual
www.deltaww.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta BX 6.0

  • Page 1 The power behind competitiveness DELTA BX_6.0 Battery Pack Operation and Installation Manual www.deltaww.com...
  • Page 3: Table Of Contents

    Table of Contents ......... . . 1 Safety .
  • Page 4 Figure 2-2 : Dimensions of DELTA BX_6.0 Battery Pack ..Figure 2-3 : Overview of DELTA BX_6.0 Battery Pack showing without Battery Module ....
  • Page 5: 1 Safety

    DELTA ELECTRONICS, INC. Service engineers and end users may not divulge the information contained herein or use this manual for purpose other than those strictly connected with correct use of the product.
  • Page 6: General Safety

    DELTA E Series hybrid solar inverter. In order to prolong Lithium-based batteries' life, 100 % state of charge (SOC) shown on the Delta E Series hybrid solar inverter is actually within the range of 95%~100%.
  • Page 7: Symbols

    Safety 1.2.2 Symbols This section describes the definition of the symbols in this manual. In order to prevent both personal injury and property damage, and to ensure long-term operation of the product, please read this section carefully and follow all the safety instructions while you use the product. DANGER! - This warning indicates an immediate hazard which will lead to death or serious injury may occur.
  • Page 8: Safety Instructions

    Safety 1.2.3 Safety Instructions The battery pack should not be installed in direct sunlight or on flammable surfaces. Please be sure to mount the battery pack tightly on a solid / smooth surface. The optimal temperature range for the battery pack to operate is 10 to  ...
  • Page 9 Safety DANGER! - This warning indicates an immediate hazard which will lead to death or serious injury may occur. (1) Electrical Shock Do not touch the terminals of the battery module without protectors. Be grounded with the specified conditions. High voltage may occur between the positive and the negative terminals. Electric shock impairs health or may cause threat to life.
  • Page 10 Safety (6) Direct Connection Do not connect the battery module to AC power or unspecified DC power. This may cause the battery module's damage to leak electrolyte, generate heat, smoke, catch fire, or explode. (7) Use in Other Equipment Do not use the battery module for any other purposes or connecting unspecified equipment.
  • Page 11 Safety WARNING ! - This warning indicates a possible hazard which may lead to death or serious injury may occur. (1) Magnetism Do not place the battery module near strong magnetism. (e.g., electromagnetic cooker, etc. ) This may cause the battery module's damage to leak electrolyte, generate heat, smoke, catch fire, or explode.
  • Page 12: 2 Introduction

    • DELTA BX_6.0 Battery Pack This user manual must be followed during installation, operation, and maintenance. The DELTA BX_6.0 Series have 1 model as shown in Figure 2-2. Delta reserves the right to make modifications to the content and technical data in this user...
  • Page 13: Product Overview

    Introduction 2.2 Product Overview The shipping components of DELTA BX_6.0 Battery Pack are shown as Figure 2-1. Figure 2-2 shows the dimensions of DELTA BX_6.0. Figure 2-3 shows the details of each portion without battery modules. ② ③ ① ④...
  • Page 14: Figure 2-2 : Dimensions Of Delta Bx_6.0 Battery Pack

    200 mm 552 mm 596 mm Figure 2-2 : Dimensions of DELTA BX_6.0 Battery Pack CAN RS-485 Comm. Standalone Switch Wall-mounting Bracket (Two Pieces besides Cabinet) Battery Cabinet Figure 2-3 : Overview of DELTA BX_6.0 Battery Pack showing without Battery Module...
  • Page 15: Figure 2-4 : Rating Labels Of Delta Bx_6.0 Battery Pack

    Introduction The following Figure 2-4 shows the rating labels of DELTA BX_6.0 Battery Pack and the table (Table 2-2) along with these labels explains the definition of the specific mark. Figure 2-4 : Rating labels of DELTA BX_6.0 Battery Pack...
  • Page 16: Led Indicators

    Introduction 2.3 LED Indicators The DELTA BX_6.0 Battery Pack has three different LED notification colors on the front cover of the battery pack that signal various system statuses: Definition LED Status Flashes red steadily Warning occurred Stays red Fault occurred...
  • Page 17: 3 Installation

    Installation 3 Installation WARNING ! - Do not install the battery pack near or on flammable surfaces. - Please mount the battery pack tightly on a solid / smooth surface. The chapter contains instructions for (1) Installation environment (2) Mechanical installation; (3) Electrical Installation; (4) Communication setup. 3.1 Installation Environment CAUTION ! - The optimal temperature range for the battery pack to operate is 10 to...
  • Page 18: Mechanical Installation

    Installation 3.2 Mechanical Installation WARNING ! - This battery pack should be installed by a trained and experienced installer designated by the retailer. - Having the product installed by a non-specialized installer is very dangerous and can cause damage or injury. CAUTION ! - Please fix at least 6 M8 Phillips head screws for the wall mounting bracket.
  • Page 19: Figure 3-1 : Recommended Space For Installation

    Installation 100 mm 100 mm 100 mm 100 mm 100 mm Figure 3-1 : Recommended Space for Installation Φ11 Figure 3-2 : Mounting bracket dimensions ( Unit: mm )
  • Page 20: Figure 3-3 : Required Position For At Least 6 Screws

    Installation Necessary for wall-mounting bracket Figure 3-3 : Required position for at least 6 screws 90° Figure 3-4 : Permitted mounting positions CAUTION ! - Please follow the instructions above such as required position for 6 screws and permitted positions for the correct installation.
  • Page 21: Figure 3-5(A) : The Procedure For Attaching The Battery Pack On The Wall

    Installation To mount the battery pack on the wall, please follow the procedure below : Mount the bracket and the battery pack at the same time. 1. Use 2 screws to fix the bottom part of the mounting bracket. Drill holes at the locations marked first. Please refer to Figure 3-2 for the wall mounting bracket dimensions.
  • Page 22: Figure 3-5(B) : Attaching The Battery Pack On The Floor

    Installation Another way to fix the battery pack is attaching on the floor, please refer to the following instruction: Be sure to select the flat floor surface for installation. Drill 4 holes with 13 mm diameter for each individual hole in order to fix the battery pack firmly as shown in Figure 3-5(b).
  • Page 23: Electrical Installation For Dc(Bt+/-)

    Installation 3.3 Electrical Installation for DC(BT+/-) DANGER : ELECTRICAL HARZARD!! - Any electric power connected to the battery pack during cabling is prohibited. - Please make sure any breaker is turned off before connecting cables. CAUTION : BATTERY DAMAGE MAY OCCUR ! - Please make sure to choose the proper size DC cable.
  • Page 24 Installation Please read the following instructions for attaching DC terminals : • It is important to choose the proper size for DC cable. • DC cable adapter must be assembled as depicted in Figure 3-6. • DC connectors are applied to DC Terminals connection as seen in Figure 3-7. •...
  • Page 25: Figure 3-6 : Assemble The Dc Connector

    Installation 18mm Figure 3-6 : Assemble the DC Connector BT Status Current Rating Wire Size Charge DC 30A 6 - 16 mm (10 - 6 AWG) Discharge DC 35A Table 3-1 : Maximum Current Ratings for Power Cables CAN RS-485 Comm. Standalone Switch Figure 3-7 : Connectors on Cabinet (Zooming from Figure 2-3 )
  • Page 26: Can And Rs-485 Communication Connection

    Installation 3.4 CAN and RS-485 Communication Connection The following figure shows communication location of DELTA BX_6.0 Battery Pack on one side of the battery cabinet. The table describes the CAN and RS-485 communication definition of the port. Please note that DC connector at both sides of the battery cabinet have the same function.
  • Page 27: Figure 3-9 : Suitable Cables For Rj45 Connector

    Installation The following instructions demonstrates the assembly procedure: RJ-45 cable without cable connector boots plug cover (soft plastic) is recommended as indicated in Figure 3-9. 1. Insert the sealing nut, seals, and support into the cable assembly. (Cable OD range: 5.0 ~ 6.5 mm.) 2.
  • Page 28: 4 Commissioning Via Standalone Operation

    Commissioning via Standalone Operation 4 Commissioning via Standalone Operation The standalone switch on the right side of the Figure 3-7 . It can wake up the battery modules when there is no utility grid. This battery pack may be useful due to backup electricity supply. It charges power electricity generated from solar panel and discharges electricity during power outages in the evening.
  • Page 29: 5 Battery Pack Expansion

    Battery Pack Expansion 5 Battery Pack Expansion WARNING ! - Before expanding the extra battery pack, please switch the battery pack power off to avoid risk of electrical shock. - Please check the battery pack regularly. If there are any impaired or loose parts, please contact your installer.
  • Page 30: 6 Trouble Shooting

    Over Discharge Current Protection our customer service for technical support Three LED 1. Check the CAN communication keep Communication fail 2. Contact your distributor / lighting our customer service for technical support Table 6-1 : Trouble shootings for DELTA BX_6.0...
  • Page 31: 7 Technical Data

    IEC 61000 - 4 -4 IEC 61000 - 4 -5 IEC 61000 - 4 -6 IEC 61000 - 4 -8 IEC 61000 - 4 -11 UN transportation testing requirements UN 3480 Section 38.3 (module) Table 7-1 : Specifications for DELTA BX_6.0...
  • Page 36 5013245001 Version 1.02 | 2016 | Oct.